Description
Medical Ti-6Al-4V ELI Titanium Wire Coil
πΉ Introduction to Medical Titanium Wire
Medical Titanium Wire is listed in coil form for component manufacturing and research. Order ASTM F136 Ti-6Al-4V ELI alloy by the specified edition, annealed condition, chemistry and required lot inspection. The device design and manufacturing process determine the finished-product evaluation requirements.
Our Medical Titanium Wire is available in precision coil form, ranging in diameter from 0.5 mm to 3.0 mm. Confirm coil inner diameter, winding arrangement, supplied condition, surface finish and required material documents with the quotation.
ELI Alloy Selection for Coil Wire
Ti-6Al-4V ELI (Extra Low Interstitial) is a lower-interstitial version of Ti-6Al-4V. Specify the ELI chemistry, annealed condition and required mechanical acceptance for the ordered wire. Medical-component projects should define the material and finished-device requirements separately.
Include the following application requirements when selecting Medical Titanium Wire:
-
Finished-device biocompatibility and intended tissue-contact evaluation
-
Finished-device magnetic and MRI assessment where required by the intended use
-
Mechanical acceptance for the supplied wire condition and component geometry
-
Chemical-exposure and sterilization-process requirements for the finished component
For permanent implantation projects, the device manufacturer should define the material specification, processing controls and finished-device evaluation for the intended contact and service conditions.
π Technical Specifications
The following entries are catalog references. For an ASTM F136 order, specify the final annealed condition; confirm any cold-drawing route or other supplied condition separately. ISO 5832-3 is a separate material specification.
| Property | Value |
|---|---|
| Alloy Grade | Ti-6Al-4V ELI |
| Standard | ASTM F136; ISO 5832-3 is a separate specification |
| Diameter Range | 0.5 mm β 3.0 mm |
| Tensile Strength | β₯ 860 MPa (annealed) |
| Elongation | β₯ 10% |
| Hardness | 25β35 HRC |
| Surface Finish | Polished / Bright / Pickled |
| Condition | Annealed or Cold Drawn |
| Coil Type | Precision wound coil, straightened on request |
| Order Documents | Mill Test Certificate, EN 10204 3.1 as ordered |
π₯ Applications of Medical Titanium Wire
Enquiries for Medical Titanium Wire may involve the following component designs. Confirm the required material condition, forming route and device validation for each intended use:
π§ Orthopedic Applications
-
Bone fixation wires
-
Cerclage wire for fracture stabilization
-
K-wires and guidewires
π¦· Dental Applications
-
Orthodontic brackets and springs
-
Arch wires and retainer systems
-
Dental implant frameworks
π§ Neurosurgical and Craniofacial Surgery
-
Skull fixation devices
-
Jawbone reconstruction
-
Maxillofacial implants
πͺ‘ Surgical Sutures and Staples
-
Biocompatible wire for soft-tissue repair
-
Flexible components in surgical closure systems
Select Medical Titanium Wire using the required coil dimensions, material condition and mechanical tests. For implantable and load-bearing medical applications, specify the finished-device evaluation and downstream manufacturing requirements.
Chemical Composition: Catalog References
| Element | Content (wt.%) |
|---|---|
| Titanium (Ti) | Balance |
| Aluminum (Al) | 5.5β6.5 |
| Vanadium (V) | 3.5β4.5 |
| Oxygen (O) | β€ 0.13 |
| Carbon (C) | β€ 0.08 |
| Iron (Fe) | β€ 0.25 |
| Nitrogen (N) | β€ 0.05 |
| Hydrogen (H) | β€ 0.0125 |
π‘ Performance in Medical Environments
For Medical Titanium Wire, define the intended manufacturing and service conditions, including:
-
Sterilization cycles (autoclave, gamma irradiation, EtO): specify the process and required finished-device evaluation.
-
Acidic and alkaline body fluids: identify exposure, contact duration and the required assessment.
-
High-fatigue environments such as orthopedic joints: define component loading and required fatigue testing.
Specify the required fatigue and corrosion assessment for the supplied condition and finished component. Review the results against the project acceptance criteria and intended service.
Material Requirements and Order Documents
For Medical Titanium Wire, list the material, inspection and documentation requirements for the order:
-
ASTM F136: specify the edition, annealed condition and required lot acceptance.
-
ISO 5832-3: a separate material specification to confirm when required by the drawing.
-
ISO 13485: state any required quality-system evidence and confirm its applicable scope.
-
RoHS & REACH: specify required declarations for quotation confirmation.
-
FDA & EU MDR: define the finished-device manufacturer documentation requirements.
Define the required methods, sampling and lot reports for the following inspection topics:
-
ICP-OES chemical analysis
-
Ultrasonic flaw detection
-
Mechanical property verification
We provide full traceability and support OEM/private label production for medical manufacturers.
π¦ Packaging and Delivery
-
π¦ Packaging: Vacuum-sealed foil bag β Clean pouch β Plastic drum
-
π« Lead Time: 7β15 business days depending on size & quantity
-
π Documents: Specify Mill Test Certificate, MSDS and RoHS document requirements with the order
-
π οΈ Customization: Coil inner diameter, surface treatment, and straightened lengths available
π Competitive Advantages
Defined material and finished-device evaluation requirements
Mechanical acceptance for the supplied wire condition
Custom coil or straightened form available
Global shipping and OEM manufacturing support
Professional technical team available for guidance
π Further Reading & References
Order Medical ELI Coil Wire
Send diameter, diameter tolerance, coil inner diameter, winding requirements, total length or weight, surface finish and quantity. Specify the F136 edition, annealed condition, required lot documents and downstream forming or sterilization process. Request a quotation for ELI coil wire.
Compare F136 straight-cut wire when cut length and straightness lead the drawing, or review Grade 23 ELI wire for a grade-led material enquiry. Browse the titanium wire category.
Coil-Wire Ordering Questions
What coil information should the drawing include? Provide inner diameter, winding arrangement, length or weight, handling requirements and any downstream straightening or forming process.
How should medical documentation be specified? List the required material lot reports and quality-system evidence, and define the device manufacturerβs finished-product assessment separately.
π Contact Us
π§ Email: sales@niticu.com
π Phone / WhatsApp / WeChat: +86 13335373172
π Factory: Baotai Road Industrial Park, High-tech Zone, Baoji City, Shaanxi, China
π Website: https://niticu.com
π© Request a quote today β our specialists will respond within 24 hours.

Reviews
There are no reviews yet.