Iridium Tantalum Anode 70:30 for Oxygen Evolution

Original price was: $400.00.Current price is: $300.00. / piece

Iridium tantalum anode with IrO₂–Ta₂O₅ MMO coating and a 70:30 molar Ir:Ta reference composition for oxygen-evolution service. Plate, mesh, tube and drawing-specific forms are available for review. Specify electrolyte, current density, temperature, active coated area and lifetime target when requesting a quotation; loading and documentation are agreed for the project.

Description

Iridium Tantalum Anode: Ir-Ta MMO for Oxygen Evolution

An Iridium Tantalum Anode is a dimensionally stable titanium electrode engineered primarily for oxygen evolution in acidic, sulfate-based, and other OER-dominated electrochemical systems.

Its active surface consists of an IrO₂–Ta₂O₅ mixed metal oxide coating supported by a commercially pure titanium substrate. Unlike an ordinary titanium component, the performance of an Iridium Tantalum Anode depends on the complete electrochemical design—including coating chemistry, Ir:Ta ratio, precious-metal loading, active area, titanium surface preparation, current density, electrolyte composition, temperature, and expected service conditions.

NiTiCu supplies custom electrodes in plate, mesh, tube, rod, perforated, and drawing-specific configurations. Grade 1 or Grade 2 titanium can be selected according to the structural requirement and project specification.

The typical coating system featured on this page uses:

Ir:Ta = 70:30 molar ratio

This composition is widely used as a reference IrO₂–Ta₂O₅ system for acidic oxygen evolution. Studies continue to use the 70:30 molar Ir:Ta formulation for Ti-based OER electrodes.

IrO₂–Ta₂O₅ MMO · 70:30 Ir:Ta · OER Focus · Custom Loading · Build to Drawing


📋 Engineering Specification

Parameter Typical Supply Engineering Note
Product Iridium Tantalum Anode Custom engineered
Substrate Titanium Grade 1 / Grade 2 Confirm per project
Active Coating IrO₂–Ta₂O₅ MMO OER-oriented system
Typical Ir:Ta Ratio 70:30 molar Other ratios by review
Main Reaction Oxygen Evolution Reaction OER
Form Plate / Mesh / Tube / Rod / Custom Drawing based
Coating Side Single / Double / Defined Area Customer specified
Active Area Customized Independent of total Ti size
Precious-Metal Loading Customized Based on operating duty
Dimensions Customer specified No fixed catalog size
Connection Tab / Lug / Bolt / Welded Assembly Drawing based
Documents Ti MTC / Coating Report / Dimensional Report As specified
Recoating Subject to substrate evaluation Case by case

An Iridium Tantalum Coated Titanium Anode should therefore be purchased as an engineered electrochemical component—not simply as a titanium plate with a black surface coating.


🧬 Understanding the 70:30 Ir:Ta Chemistry

The “70:30” specification requires careful definition.

For this product, it refers to:

Ir:Ta = 70:30 molar ratio

It should not automatically be interpreted as a 70:30 weight ratio of finished IrO₂ and Ta₂O₅.

That distinction matters when technical specifications, coating reports, and purchase orders are prepared.

Role of Each Component

Component Main Function
IrO₂ Principal electrocatalytic component for oxygen evolution
Ta₂O₅ Stabilizing component within the MMO system
Titanium Conductive, corrosion-resistant structural substrate
70:30 Ir:Ta Widely used molar reference composition

IrO₂ is strongly associated with electrocatalytic oxygen evolution, while addition of Ta₂O₅ improves stability of the mixed oxide system. IrO₂–Ta₂O₅ coatings on titanium are well established as acidic OER electrodes.

However, an Iridium Tantalum Anode should not be selected by coating ratio alone.

The final design also needs to consider:

Electrolyte · Current Density · Temperature · Active Area · Loading · Duty Cycle · Lifetime Target

For this reason, NiTiCu treats 70:30 as an important reference composition rather than claiming it is universally optimal for every electrochemical process.


⚡ Oxygen Evolution Is the Main Design Direction

The principal purpose of an Iridium Tantalum Anode is oxygen evolution.

This is one of the most important things to make clear when comparing different MMO titanium anodes.

Not every MMO chemistry is designed for the same anodic reaction.

Electrochemical Duty Typical Coating Direction
Oxygen Evolution / OER IrO₂–Ta₂O₅
Acidic Sulfate Electrolysis Ir-Ta MMO
Copper Foil Electrolysis Ir-Ta MMO
Electrowinning with OER Ir-Ta MMO
OER-Type Electroplating Ir-Ta MMO
High-Chloride Chlorine Evolution Usually Ru-Ir-based system
Brine / Hypochlorite Generation Usually chlorine-evolution coating

Commercial Ir-Ta MMO systems are primarily positioned for acidic industrial electrolysis and oxygen evolution, while chloride-evolving brine processes are normally treated separately with Ru-Ir coating systems.

This is why an Oxygen Evolution Anode should be specified according to the actual anodic reaction rather than simply ordered as an “MMO titanium anode.”


📐 Titanium Substrate & Active Coating Area

The titanium substrate performs several functions:

  • mechanical support;
  • electrical conduction;
  • dimensional stability;
  • structural connection to the electrolysis system.

But the overall titanium dimensions and the active coated area are not necessarily identical.

An Iridium Tantalum Anode may include intentionally uncoated regions for electrical connection, welding, clamping, sealing, or current distribution.

Design Item Available Configuration
Substrate Grade Grade 1 / Grade 2
Shape Plate / Mesh / Tube / Rod / Perforated / Custom
Thickness Drawing specified
Width & Length Drawing specified
Active Area Full surface / Defined area
Coating Side Single / Double
Contact Area Can remain uncoated
Electrical Connection Tab / Lug / Bolt / Welded structure
Masking / Edge Area Drawing specified

Current industrial Ir-Ta suppliers offer plate, mesh, rod, wire, tube, basket, and custom titanium assemblies, illustrating how strongly the final geometry depends on the actual electrochemical system.

For a large Iridium Tantalum Coated Titanium Anode, defining the active coated area separately from the overall titanium size is especially important because precious-metal loading is normally related to the actual coated surface.


🔬 Titanium Surface Preparation

The coating/substrate interface is one of the most critical parts of an IrO2-Ta2O5 Titanium Anode.

Before coating, the titanium surface must be prepared to remove contamination and create a suitable interface for the active layer.

A typical process logic may include:

Degreasing → Surface Conditioning → Chemical Activation → Rinsing → Drying

The exact acid chemistry, concentration, temperature, and treatment time are manufacturing parameters rather than universal product specifications.

Research has shown that different titanium pretreatment methods can substantially change the lifetime of IrO₂–Ta₂O₅/Ti electrodes, even when their apparent electrochemical activity is relatively similar. Interfacial detachment has also been identified as an important degradation mechanism.

This means surface preparation is not a cosmetic step.

For an Iridium Tantalum Anode, good substrate preparation helps establish the interface on which the entire active coating depends.


🔥 Multi-Layer Coating & Thermal Conversion

The active layer is not normally created by applying one thick coating in a single operation.

A controlled Iridium Tantalum Anode manufacturing process generally builds the active oxide system through repeated coating and thermal conversion steps.

Typical Process Logic

Precursor Application → Drying → Thermal Decomposition → Cooling → Repeat Coating Cycles → Final Heat Treatment

During heating, the Ir- and Ta-containing precursor is converted into the mixed oxide layer.

Repeated cycles allow the active material to be built progressively and more controllably.

Published IrO₂–Ta₂O₅/Ti preparation routes commonly use thermal decomposition of precursor layers, and coating morphology and electrochemical performance can be strongly influenced by thermal treatment conditions.

The number of cycles itself should not be treated as the primary purchasing specification.

What matters more is whether the final Iridium Tantalum Anode meets the required chemistry, loading, coated area, and operating performance.


📊 Ratio, Loading & Thickness Are Not the Same Thing

This is one of the most important technical distinctions on the entire page.

Four concepts are often confused:

Parameter Actual Meaning
Ir:Ta Ratio Chemical relationship between Ir and Ta in the coating system
Precious-Metal Loading Quantity of Ir / active precious metal per unit coated area
Physical Coating Thickness Geometric thickness of the oxide coating
Coating Cycles Manufacturing-process variable

These numbers are related—but they cannot be substituted for one another.

For example:

“Coating thickness = 10 μm”

does not by itself tell the buyer how much iridium is present per square meter.

Likewise:

“Ir:Ta = 70:30”

does not specify the total amount of active material on the titanium.

For an Iridium Tantalum Anode, precious-metal loading is therefore an important engineering parameter and should be matched to the actual electrochemical duty.

NiTiCu can review loading requirements according to:

Current Density · Electrolyte · Temperature · Active Area · Duty Cycle · Required Lifetime


📋 Design the Anode Around the Electrolyte

An Iridium Tantalum Anode should not be designed from dimensions alone.

A drawing that says only:

900 × 700 × 2 mm

is useful mechanically, but it does not provide enough information to engineer the active coating.

The operating environment is equally important.

Project Information Why It Matters
Electrolyte Defines the electrochemical environment
Acid / Salt Concentration Influences coating stability
Current Density Major factor in coating duty
Operating Temperature Affects kinetics and degradation
Required Service Life Defines durability target
Active Area Determines current distribution
Single / Double Side Changes total coated area
Total Dimensions Determines equipment fit
Connection Design Controls mechanical/electrical installation

Current density, solution chemistry, preparation method, and interfacial condition have all been shown to affect the lifetime of IrO₂–Ta₂O₅/Ti electrodes.

That is why the correct Oxygen Evolution Anode should be engineered around the electrolyte and duty—not selected from a universal catalog specification.


🏭 Industrial Application Matrix

An Iridium Tantalum Anode is most appropriate where oxygen evolution is the dominant anodic process.

Application Main Design Focus
Electrolytic Copper Foil Acidic sulfate electrolyte, high current, active-area uniformity
Metal Electrowinning Electrolyte compatibility, current density, lifetime
Electroplating OER-based anodic reaction and process chemistry
Electroforming Stable insoluble anode performance
Acidic Electrolysis OER activity and coating durability
Water Electrolysis / R&D Controlled OER studies
Electrochemical Treatment Process-specific electrolyte review

Ir-Ta coated titanium electrodes are commercially used in electrolytic copper foil, electroplating, electrowinning, and other acidic oxygen-evolution processes.

Electrolytic Copper Foil

In acidic copper sulfate systems, the Iridium Tantalum Coated Titanium Anode operates as a dimensionally stable oxygen-evolving electrode.

Large plate systems may require careful attention to:

Current Distribution · Active Area · Loading Uniformity · Flatness · Electrical Connection

Electrowinning

An Ir-Ta MMO Anode can be considered in selected electrowinning processes where OER dominates at the anode.

The exact electrolyte must still be reviewed because “electrowinning” alone does not define the corrosion environment.

Electroplating & Electroforming

Where the process uses an insoluble oxygen-evolving anode, Ir-Ta MMO can provide a stable titanium-based electrode platform.


⏳ Service Life — Avoid Universal Numbers

It would be technically misleading to write:

Service life: 5 years

or:

Service life: 10 years

for every Iridium Tantalum Anode.

Actual life depends strongly on operating conditions.

Main Lifetime Variables

Current Density
Electrolyte Composition
Temperature
Precious-Metal Loading
Titanium Pretreatment
Coating Microstructure
Active Area
Duty Cycle

Studies of Ti/IrO₂–Ta₂O₅ electrodes show that pretreatment, interface condition, thermal processing, and electrochemical test conditions all affect durability. ScienceDirect

Possible degradation mechanisms include:

  • gradual active coating loss;
  • interfacial deterioration;
  • local coating detachment;
  • growth of resistive titanium oxide;
  • increasing anode potential.

Therefore, service-life expectations should always be discussed together with the customer’s real operating conditions.


♻️ Recoating & Substrate Reuse

The titanium substrate can represent a significant part of the finished anode structure.

When the active coating reaches the end of its useful life, a used Iridium Tantalum Anode may sometimes be evaluated for recoating instead of being completely replaced.

Recoating Evaluation Route

Old Coating Removal → Titanium Inspection → Dimensional Check → Surface Reactivation → New MMO Coating

Recoating may be practical when the titanium:

  • remains structurally sound;
  • has not suffered severe thinning;
  • has no unacceptable deep corrosion;
  • retains usable electrical connections;
  • remains dimensionally suitable.

Commercial Ir-Ta suppliers also offer recoating after inspection of used titanium substrates.

An Ir-Ta MMO Anode should therefore be inspected before recoating rather than automatically reused.


🔍 Quality Control & Traceability

An Iridium Tantalum Anode requires a different inspection philosophy from ordinary titanium plate.

Quality control must consider both the titanium substrate and the active MMO system.

Inspection Item Typical Control
Titanium Material Grade / material verification
Dimensions Drawing inspection
Coating Chemistry Ir-Ta MMO system
Ir:Ta Ratio According to specification
Precious-Metal Loading As specified
Coated Area Single / double / defined surface
Surface Coverage Visual inspection
Connection Structure Drawing verification
Electrochemical Test On request
Third-Party Inspection On request

Documentation Structure

Titanium MTC
Substrate grade and material traceability.

Coating Report
Ir-Ta system, ratio, and loading where specified.

Dimensional Report
Finished electrode dimensions and key features.

Inspection Report
Project-specific inspection results.

EN 10204 3.1
Can be discussed for applicable substrate material when required.

This document structure provides significantly more useful information than a single generic “COA.”



Iridium Tantalum Anode FAQ

What is an iridium tantalum anode used for?

An iridium tantalum anode is a titanium electrode with an IrO₂–Ta₂O₅ MMO coating for oxygen evolution. It is considered for acidic sulfate electrolysis, copper foil, electrowinning and compatible electroplating processes. Confirm the electrolyte and dominant anodic reaction before choosing the coating.

What does a 70:30 Ir:Ta ratio mean?

For the reference system on this page, 70:30 means the molar ratio of iridium atoms to tantalum atoms. It is not a 70:30 weight ratio of the finished oxides and does not specify precious-metal loading. The quotation and coating report should state the ratio basis explicitly.

Can coating thickness determine iridium loading or service life?

No. Physical thickness, iridium loading per unit coated area and coating chemistry are separate specifications. A loading figure should identify the measured metal, units and area basis. Service life also depends on electrolyte, current density, temperature, substrate preparation and operating cycle; an accelerated test result is not a universal field-life guarantee.

Should I choose Ir-Ta MMO or Ru-Ir MMO for brine electrolysis?

Ir-Ta MMO is primarily associated with oxygen-evolution duty. For chloride-rich electrochlorination and sodium hypochlorite production, compare the Ru-Ir sodium hypochlorite anode. Coating selection must follow the actual cell chemistry and operating window.

Related Anodes and Quotation Guidance

Browse titanium anodes and read the MMO titanium anode manufacturing guide. For a custom quotation, use the purchasing guide and include the cell drawing, electrolyte, active area, current density, temperature and intended duty.

Technical References

The 2025 study of IrO₂–Ta₂O₅/Ti anodes in acidic oxygen evolution uses a 70:30 molar Ir:Ta formulation and examines deactivation. A separate study of titanium substrate pretreatment evaluates its effect on electrode behavior and lifetime. These research results explain design factors; the agreed order specification defines the supplied electrode.

Why NiTiCu?

NiTiCu treats MMO titanium electrodes as electrochemical engineering products, not generic coated titanium parts.

Electrochemical Design Custom Fabrication Quality Control
70:30 Ir:Ta reference system Plate / Mesh / Tube / Custom Titanium traceability
Loading matched to operating duty Defined active area Coating documentation
OER-focused coating selection Custom connection design Dimensional inspection

Each Iridium Tantalum Anode can be reviewed against the actual:

Electrolyte · Current Density · Temperature · Active Area · Geometry · Lifetime Objective

The operating environment defines the anode—not the other way around.


✦ PROJECT ACCESS

🟢 01 — WHATSAPP

+86 133 3537 3172


✉️ 02 — SALES EMAIL

sales@niticu.com


🕒 03 — RESPONSE

Normally within 24 hours

Reviews

There are no reviews yet.

Be the first to review “Iridium Tantalum Anode 70:30 for Oxygen Evolution”

Your email address will not be published. Required fields are marked *

Need a custom size or quantity?